# Lockout/tagout

> Lockout/tagout (LOTO) means cutting a machine's power and locking or tagging the switch before repairs. OSHA's standard is 29 CFR 1910.147.

Source: https://incidentkit.ai/glossary/lockout-tagout · Updated Oct 5, 2026

Also known as: LOTO, control of hazardous energy, 29 CFR 1910.147

## What the standard requires

29 CFR 1910.147 covers service and repair of machines where a sudden start-up, or release of stored energy, could hurt workers. The employer must run an energy control program with three parts: procedures, training and inspections.

- Use lockout if the energy device can be locked, unless tagout gives full protection.
- Use tagout where the device cannot be locked. A tag is a warning, not a block.
- Inspect each procedure at least yearly.
- The inspector must be an authorized employee (one trained to lock out machines) who does not use it.
- Train authorized employees on energy sources and shutoff steps. Tell other employees about the procedures.

## Scope and an example

The standard does not cover construction, agriculture, some maritime work, power utilities, electrical hazards under subpart S, or oil and gas well work. Normal production is covered only when, for example, a guard is removed or bypassed.

Example: a technician clearing a jam on a packaging line shuts the line down, locks the breaker, adds a personal tag and checks that the line cannot start before reaching in. A LOTO failure with no injury is a [PSIF](https://incidentkit.ai/glossary/psif)-type event that needs investigation.

Mix-up: LOTO applies to service and repair, not every machine stop, and a tag alone does not stop energy. It is one control among many on the [hierarchy of controls](https://incidentkit.ai/glossary/hierarchy-of-controls).

## Frequently asked questions

### How often must lockout/tagout procedures be inspected?

At least yearly, by an authorized employee who does not use the procedure. The inspection must fix any gaps. For lockout, the inspector also reviews duties with each authorized employee.

### Does 29 CFR 1910.147 apply to construction?

No. It excludes construction and agriculture, plus some maritime work, utility installations and a few other types. Check the construction standards instead.

### Is tagout alone acceptable?

Only where the device cannot be locked out, or where the employer shows tagout gives full protection. Lockout is the default when the device can be locked.

## Sources

- [OSHA 29 CFR 1910.147: The control of hazardous energy (lockout/tagout)](https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147)

## Related terms

- [Hierarchy of controls](https://incidentkit.ai/glossary/hierarchy-of-controls)
- [PSIF (potential serious injury or fatality)](https://incidentkit.ai/glossary/psif)
- [Near miss](https://incidentkit.ai/glossary/near-miss)
- [OSHA recordable injury](https://incidentkit.ai/glossary/osha-recordable)

## Related

- [Lockout/tagout 29 CFR 1910.147: program and event data](https://incidentkit.ai/compliance/osha/lockout-tagout)
- [Manufacturing incident reporting and OSHA 300 software](https://incidentkit.ai/solutions/manufacturing)
- [Incident reporting software for plant managers](https://incidentkit.ai/solutions/plant-managers)
- [Warehouse and logistics incident reporting software](https://incidentkit.ai/solutions/warehousing-and-logistics)
- [Near Miss Report Template (Free, Printable Form)](https://incidentkit.ai/templates/near-miss-report)
- [Workplace Injury Reporting: Steps, Deadlines, Records](https://incidentkit.ai/use-cases/workplace-injury-reporting)